- Sequence used to identify regions of fatty infiltration and help identify adenomas.
- aka chemical shift imaging
- Relies of differences in the precessional frequency of Hydrogen in fat and water molecules.
- Gradient echo image with TE set to a time where fat and water spins are 180 degrees out of phase causing fat and water signal components within a voxel to destructively interfere and reduce the brightness of the pixel.
- Degree of signal change depends on the ration of fat/water. All fat or all water, no signal drop (compared to in-phase image) 50/50 causes total signal loss
- OOP images identified by dark bands at fat water interfaces
- Select the shortest OOP TE to get best T1 contrast and largest number of slices
- Exact TE depends on filed strength
T1 Out of Phase (OOP) images in Abdominal imaging
Subscribe to:
Post Comments (Atom)
Popular Posts
-
3-PLANE LOC AXIAL T1 AXIAL T2 FS CORONAL T1 CORONAL STIR Axial T2 high resolution FIESTA ( Facial Nerves in IAC for any space occu...
-
Magnetic resonance imaging (MRI) cisternography depends on heavily T2-weighted sequences with fat suppression. CSF appears as a bright s...
-
Regional Saturation Bands Regional saturation employs a 90° RF pulse which, when combined with a gradient orthogonal to the imaging p...
-
SOURCE: http://imageradiology.blogspot.com/2012/06/3d-mrcp-pancreas.html The 3D TSE sequence can produce high-spatial-resolution MRCP...
-
The sternum and sternoclavicular joints are difficult to evaluate with plain radiographs. The value of CT in assessing lesions of the...
-
Normal MRI Anatomy The pectoralis tendon is best seen on axial T1 and T2-weighted images as a curvilinear low-signal band inserting o...
-
--> Indications : evaluating for meniscal retears in a postoperative knee. Sequences Knee MR arthrogram MRI Protocol : ...
-
Because MR neurography sequences are relatively lengthy and motion sensitive, it is not generally feasible to screen the whole extremity ...
-
Prostrate MRI Appearence T1‐weighted MR images, the normal prostate gland demonstrates homogeneous intermediate to‐ low signal inten...
No comments:
Post a Comment