Indications: characterize and follow-up
inflammatory arthritides in the hands and wrists.
Sequences: scan through each
hand/wrist separately, using the wrist coil.
·
Coronal T1 spin echo
·
Coronal 2-D FLASH with fat saturation
·
Coronal ‘gray’ STIR
·
Coronal post-Gadolinium T1 spin echo with fat saturation.
Comments:
·
If both hand/wrists are ordered, schedule as 2 separate exams.
·
Use 3 mm slice thickness for all sequences.
·
Reference: Schoellnast et al. AJR 2006; 187: 351-357.
Dictation
template:
Coronal T1 and ‘gray’ STIR, 2-D FLASH with fat
saturation. After the administration of
0.1-0.4 mmol/kg of intravenous Gadolinium contrast (up to 20 mL), coronal T1
spin echo with fat saturation images acquired through the hand and wrist.
No comments: