Phased array coils are placed cover the anatomic region of interest. After scouts and routine pre-contrast T1 and T2 weighted images (if needed) are obtained, a 3D pre-contrast MRA sequence (3D FLASH, typical parameters 3.4/1.3/25; 1.2-1.7mm slice thickness with the acquisition time < 10 seconds) is prescribed over the vascular region of interest. Subsequently multiple consecutive 3D CE-MRA data sets are initiated as contrast medium is injected. The number of repetitive measurements depends on the acquisition time of each single MRA data set. Typically a total acquisition time of 60-120 seconds is required to cover circumstances such as slow arterial inflow, and to make sure venous outflow is visualized. No timing exam is necessary. 15-20 mL of gadolinium-DPTA is generally required for a single station. The injection of contrast is performed using an MR-compatible remote-controlled power injector followed by 20mL of saline. The injection rate for both contrast and saline is set to 2-3 mL/second. When the upper extremity is being imaged, the contrast should be administered into the contralateral arm vein. Automatic inline subtraction of the first (nonenhanced) 3D volume from the subsequent identical 3D volumes obtained during and after contrast administration should be used, if available. Subsequently a 3D fat suppressed gradient echo sequence using the volumetric interpolated breathhold examination (VIBE) can be performed with a larger FOV through the area of interest ( TR/TE, 3.5/1.5; flip angle, 12ยบ; slice thickness, 2-3mm;) for general anatomic survey.
Time-Resolved MRA Protocol
Phased array coils are placed cover the anatomic region of interest. After scouts and routine pre-contrast T1 and T2 weighted images (if needed) are obtained, a 3D pre-contrast MRA sequence (3D FLASH, typical parameters 3.4/1.3/25; 1.2-1.7mm slice thickness with the acquisition time < 10 seconds) is prescribed over the vascular region of interest. Subsequently multiple consecutive 3D CE-MRA data sets are initiated as contrast medium is injected. The number of repetitive measurements depends on the acquisition time of each single MRA data set. Typically a total acquisition time of 60-120 seconds is required to cover circumstances such as slow arterial inflow, and to make sure venous outflow is visualized. No timing exam is necessary. 15-20 mL of gadolinium-DPTA is generally required for a single station. The injection of contrast is performed using an MR-compatible remote-controlled power injector followed by 20mL of saline. The injection rate for both contrast and saline is set to 2-3 mL/second. When the upper extremity is being imaged, the contrast should be administered into the contralateral arm vein. Automatic inline subtraction of the first (nonenhanced) 3D volume from the subsequent identical 3D volumes obtained during and after contrast administration should be used, if available. Subsequently a 3D fat suppressed gradient echo sequence using the volumetric interpolated breathhold examination (VIBE) can be performed with a larger FOV through the area of interest ( TR/TE, 3.5/1.5; flip angle, 12ยบ; slice thickness, 2-3mm;) for general anatomic survey.
Subscribe to:
Post Comments (Atom)
Popular Posts
-
Axial Plane: Prescribe plane perpendicular to midshaft of the proximal phalanx of the thumb. Scan from 1st carp-metacarpal joint th...
-
Normal and a rupture Achilles tendon MRI images Achilles tendon MRI image-yellow arrow Green-normal Achilles tendon MRI image ...
-
MR Arthrogram Protocol Axial T1 SE Axial T1 SE (fat sat) Sagittal Obl T1 SE (fat sat) Coronal Obl T1 SE (fat sat) Coronal Obl T2 TSE ...
-
Normal MRI Anatomy The pectoralis tendon is best seen on axial T1 and T2-weighted images as a curvilinear low-signal band inserting o...
-
MRI Prostrate Spectroscopy SINGLE VOXEL Planning --> MRI Prostrate Spectroscopy MULTI VOXEL Planning
-
ABER Protocol for MRI Shoulder Align from coronal scout perpendicular to glenohumeral joint line (perpendicular to glenoid) Ideally th...
-
--> Patients are positioned in the supine or left decubitus position. Claustrophobic reactions have not been observed to a higher...
-
Horizontal long axis: known as a 4-chamber view. Short axis plane-multiple/contiguous Vertical long axis: known as a 2-chamber view ...
-
Prescribing sagittal images. Images are obtained no more than 10° oblique to a perpendicular to a line connecting the ...
1 comment:
Nice post
MRI Scan Cost in Delhi may vary from Rs. 3000/- to Rs.8000/- in 1.5 Tesla to 3 Tesla according to for one part of the body. Now book your scan through easybookmylab
Post a Comment