Gradient echo (GE) in spinal MR imaging does not use a 180° pulse to achieve the echo. This gradient-driven echo allows for rapid imaging with very short repetition time (TR). Intrinsic to good image quality in GE imaging is the choice of flip angle, which has optimal values for specific TRs and tissue types, the Ernst angle (the longer the T1 of the tissue, the smaller the best flip angle). There are two types of GE imaging; spoiled and steady-state. Spoiled sequences (fast low-angle shot [FLASH] and spoiled gradient-recalled acquisition in steady state [GRASS]) destroy the residual transverse magnetization after each alpha pulse. In steady-state sequences (fast-imaging steady precession [FISP], steady-state free precession [SSFP], and GRASS), this transverse magnetization is maintained and stabilizes after a few pulses. For tissue with a short T2 (e.g., fat, muscle), or sequences requiring long TR, the spoiled and steady-state sequences look the same. If the T2 of interest is long (e.g., CSF), then the steady-state sequence will give the familiar CSF myelogram effect. Flip angle is a powerful modifier of GE contrast. Spoiled GE sequences will be more T1-weighted with higher flip angles approaching 90°. For steady-state sequences where the TR is shorter than the T2, tissues with long T1 and T2 will show preferentially increased signal with increasing flip angle. Spin-density images can be obtained with a GE technique with short TR if a small flip angle is used. T2-like contrast (T2*) can be obtained with increasing echo time (TE), as with conventional SE imaging.
-->
Subscribe to:
Post Comments (Atom)
Popular Posts
-
3-PLANE LOC AXIAL T1 AXIAL T2 FS CORONAL T1 CORONAL STIR Axial T2 high resolution FIESTA ( Facial Nerves in IAC for any space occu...
-
Magnetic resonance imaging (MRI) cisternography depends on heavily T2-weighted sequences with fat suppression. CSF appears as a bright s...
-
Regional Saturation Bands Regional saturation employs a 90° RF pulse which, when combined with a gradient orthogonal to the imaging p...
-
SOURCE: http://imageradiology.blogspot.com/2012/06/3d-mrcp-pancreas.html The 3D TSE sequence can produce high-spatial-resolution MRCP...
-
Prostrate MRI Appearence T1‐weighted MR images, the normal prostate gland demonstrates homogeneous intermediate to‐ low signal inten...
-
MP-RAGE stands for Magnetisation Prepared RApid Gradient Echo. MP-RAGE is a 3DFT contrast prepared gradient echo sequence. The T1 weig...
-
--> Indications : evaluating for meniscal retears in a postoperative knee. Sequences Knee MR arthrogram MRI Protocol : ...
-
Axial Plane: Prescribe plane perpendicular to midshaft of the proximal phalanx of the thumb. Scan from 1st carp-metacarpal joint th...
-
CERVICAL MYELOGRAM LUMBAR MYELOGRAM Technique Single-slice MR myelography was ...
-
High Resolution Brainstem Imaging CISS (Constructive Interference Steady State) CISS is a strongly T2 weighted GRE sequence. In essen...
No comments:
Post a Comment