DWI measures the random Brownian motion of water molecules in tissues and can hence assess tissue microstructure and tumor cellularity based on the apparent diffusion coefficient (ADC).[5] Lower ADC values correspond to well-organized tissue and high cellularity; higher ADC values correspond to low cellularity and not well-organized tissue. Thus high-grade or very cellular tumors (eg, lymphoma, Figure 4) may show lower ADC values. Similarly, increasing ADC values after treatment might indicate treatment response because tumor cell density decreases with cell death and leads to increase in the extravascular extracellular space (EES). However, there is considerable overlap, and thus the ADC value alone may be insufficient to predict the tumor grade.Diffusion-weighted imaging in Brain tumors
DWI measures the random Brownian motion of water molecules in tissues and can hence assess tissue microstructure and tumor cellularity based on the apparent diffusion coefficient (ADC).[5] Lower ADC values correspond to well-organized tissue and high cellularity; higher ADC values correspond to low cellularity and not well-organized tissue. Thus high-grade or very cellular tumors (eg, lymphoma, Figure 4) may show lower ADC values. Similarly, increasing ADC values after treatment might indicate treatment response because tumor cell density decreases with cell death and leads to increase in the extravascular extracellular space (EES). However, there is considerable overlap, and thus the ADC value alone may be insufficient to predict the tumor grade.
Subscribe to:
Post Comments (Atom)
Popular Posts
-
Axial Plane: Prescribe plane perpendicular to midshaft of the proximal phalanx of the thumb. Scan from 1st carp-metacarpal joint th...
-
Normal MRI Anatomy The pectoralis tendon is best seen on axial T1 and T2-weighted images as a curvilinear low-signal band inserting o...
-
--> Patients are positioned in the supine or left decubitus position. Claustrophobic reactions have not been observed to a higher...
-
3-PLANE LOC AXIAL T1 AXIAL T2 FS CORONAL T1 CORONAL STIR Axial T2 high resolution FIESTA ( Facial Nerves in IAC for any space occu...
-
--> Routine shoulder protocols are the most variable, but most include SHOULDER MRI SEQUENCES ...
-
Like any technique, fMRI has advantages and disadvantages, and in order to be useful, the experiments that employ it must be carefully desi...
-
Prescribing sagittal images. Images are obtained no more than 10° oblique to a perpendicular to a line connecting the ...
No comments: