Indications: evaluate for sinus
thrombosis.
Sequences:
·
Sagittal T1 spin echo
·
Coronal 2-D time-of-flight with inferior saturation band
·
Rotating 3-D MIP reformats of venous structures
Comments:
·
Suggested 2D TOF parameters: TR/TE = 32-40/8-12; flip angle 50-70
degrees, slice thickness 1.5-3.0 mm, 144 x 256 matrix, NEX 1-2.
Dictation
template:
Sagittal
T1 spin echo through the brain. Coronal
2D time-of-flight MR venogram, with 3-dimensional maximum-intensity-projection
(MIP) reformats of the intracranial veins then performed.
No comments: