Double-Contrast Protocol for MR Imaging of the Liver at 1.5 T



Administer an infusion of SPIO particles over 30 minutes,then wait 30-60 minutes
  • Coronal single shot echo train spin echo sequence
  • Axial T2 * 2D spoiled GRE sequence
  • Axial breathe hold T2 echo train spin echo
  • Axial T1 weighted 3D spoiled GRE pre contrast
POST  CONTRAST
  • Axial T1 3D spoiled GRE -Hepatic arterial phase+portal venous phase+equilibrium phase
  • Axial T2 * 2D spoiled GRE sequence Axial optional Coronal with Fat Sat
-->