The peak blood concentration of injected gadopentetate dimeglumine depends on the bolus injection rate (12–14). The signal intensity obtained with the spoiled GRE sequences (3D fast field echo and 3D turbo field echo) increases according to the gadopentetate dimeglumine concentration . Therefore, with a spoiled GRE sequence, a fast injection rate (2–5 mL/sec) is used. However, a nonspoiled GRE sequence does not show high signal intensity when the maximum gadopentetate dimeglumine concentration reaches more than 2 mmol/L. Therefore, with a nonspoiled GRE sequence, slow injection of nondiluted gadopentetate dimeglumine or rapid injection of diluted gadopentetate dimeglumine would be recommended.
Injection Rate of Dynamic MR angiogram
The peak blood concentration of injected gadopentetate dimeglumine depends on the bolus injection rate (12–14). The signal intensity obtained with the spoiled GRE sequences (3D fast field echo and 3D turbo field echo) increases according to the gadopentetate dimeglumine concentration . Therefore, with a spoiled GRE sequence, a fast injection rate (2–5 mL/sec) is used. However, a nonspoiled GRE sequence does not show high signal intensity when the maximum gadopentetate dimeglumine concentration reaches more than 2 mmol/L. Therefore, with a nonspoiled GRE sequence, slow injection of nondiluted gadopentetate dimeglumine or rapid injection of diluted gadopentetate dimeglumine would be recommended.
Subscribe to:
Post Comments (Atom)
Popular Posts
-
Axial Plane: Prescribe plane perpendicular to midshaft of the proximal phalanx of the thumb. Scan from 1st carp-metacarpal joint th...
-
Like any technique, fMRI has advantages and disadvantages, and in order to be useful, the experiments that employ it must be carefully desi...
-
Normal MRI Anatomy The pectoralis tendon is best seen on axial T1 and T2-weighted images as a curvilinear low-signal band inserting o...
-
--> Routine shoulder protocols are the most variable, but most include SHOULDER MRI SEQUENCES ...
-
3-PLANE LOC AXIAL T1 AXIAL T2 FS CORONAL T1 CORONAL STIR Axial T2 high resolution FIESTA ( Facial Nerves in IAC for any space occu...
-
Magnetic resonance imaging (MRI) cisternography depends on heavily T2-weighted sequences with fat suppression. CSF appears as a bright s...
-
Normal and a rupture Achilles tendon MRI images Achilles tendon MRI image-yellow arrow Green-normal Achilles tendon MRI image ...
-
SAGITAL ORBIT MRI PLANNING REFERRAL LINES AXIAL ORBIT MRI PLANNING REFERRAL LINES CORONAL ORBIT MRI PLANNING REFERRAL ...
No comments:
Post a Comment