This limitation can be somewhat addressed with the dynamic coronal MRCP sequence. Simply prescribe a slice in the coronal plane directly through the level of the CBD as prescribed earlier in the Coronal Oblique 3 Slab MRCP sequence. Next, instruct the patient to hold a breath on suspended expiration and repeat this sequence six times, thereby acquiring six images at the same location. This is achieved by either clicking on the mouse button to scan, or by pressing the scan button on the keyboard six times. The resulting images should demonstrate fluid drainage into the duodenum or obstruction or strictures along the CBD.