Phased array coils are placed cover the anatomic region of interest. After scouts and routine pre-contrast T1 and T2 weighted images (if needed) are obtained, a 3D pre-contrast MRA sequence (3D FLASH, typical parameters 3.4/1.3/25; 1.2-1.7mm slice thickness with the acquisition time < 10 seconds) is prescribed over the vascular region of interest. Subsequently multiple consecutive 3D CE-MRA data sets are initiated as contrast medium is injected. The number of repetitive measurements depends on the acquisition time of each single MRA data set. Typically a total acquisition time of 60-120 seconds is required to cover circumstances such as slow arterial inflow, and to make sure venous outflow is visualized. No timing exam is necessary. 15-20 mL of gadolinium-DPTA is generally required for a single station. The injection of contrast is performed using an MR-compatible remote-controlled power injector followed by 20mL of saline. The injection rate for both contrast and saline is set to 2-3 mL/second. When the upper extremity is being imaged, the contrast should be administered into the contralateral arm vein. Automatic inline subtraction of the first (nonenhanced) 3D volume from the subsequent identical 3D volumes obtained during and after contrast administration should be used, if available. Subsequently a 3D fat suppressed gradient echo sequence using the volumetric interpolated breathhold examination (VIBE) can be performed with a larger FOV through the area of interest ( TR/TE, 3.5/1.5; flip angle, 12ยบ; slice thickness, 2-3mm;) for general anatomic survey.
Time-Resolved MRA Protocol
Phased array coils are placed cover the anatomic region of interest. After scouts and routine pre-contrast T1 and T2 weighted images (if needed) are obtained, a 3D pre-contrast MRA sequence (3D FLASH, typical parameters 3.4/1.3/25; 1.2-1.7mm slice thickness with the acquisition time < 10 seconds) is prescribed over the vascular region of interest. Subsequently multiple consecutive 3D CE-MRA data sets are initiated as contrast medium is injected. The number of repetitive measurements depends on the acquisition time of each single MRA data set. Typically a total acquisition time of 60-120 seconds is required to cover circumstances such as slow arterial inflow, and to make sure venous outflow is visualized. No timing exam is necessary. 15-20 mL of gadolinium-DPTA is generally required for a single station. The injection of contrast is performed using an MR-compatible remote-controlled power injector followed by 20mL of saline. The injection rate for both contrast and saline is set to 2-3 mL/second. When the upper extremity is being imaged, the contrast should be administered into the contralateral arm vein. Automatic inline subtraction of the first (nonenhanced) 3D volume from the subsequent identical 3D volumes obtained during and after contrast administration should be used, if available. Subsequently a 3D fat suppressed gradient echo sequence using the volumetric interpolated breathhold examination (VIBE) can be performed with a larger FOV through the area of interest ( TR/TE, 3.5/1.5; flip angle, 12ยบ; slice thickness, 2-3mm;) for general anatomic survey.
Subscribe to:
Post Comments (Atom)
Popular Posts
-
Like any technique, fMRI has advantages and disadvantages, and in order to be useful, the experiments that employ it must be carefully desi...
-
MRI Prostrate Spectroscopy SINGLE VOXEL Planning --> MRI Prostrate Spectroscopy MULTI VOXEL Planning
-
Sagital T1 (whole head left to right) Axial Flair (brain) Ax T2 hi-res 3D FSE (symphysis of mandible to superior orbit) Cornonal T2...
-
MR Arthrogram Protocol Axial T1 SE Axial T1 SE (fat sat) Sagittal Obl T1 SE (fat sat) Coronal Obl T1 SE (fat sat) Coronal Obl T2 TSE ...
-
MRI OF THE RIGHT ANKLE JOINT. Clinical details: Fall and twisting injury to the Right Ankle 8 months ago. Now pain around the Ank...
-
The sternum and sternoclavicular joints are difficult to evaluate with plain radiographs. The value of CT in assessing lesions of the...
-
Respiration Artefact Reduction ROPE Respiratory ordered phase encoding collects centre of K-space when respiratory motion is minim...
-
In gradient echo (GRE) imaging, the TR is often shorter than the T2 of most tissues, and the transverse magnetization will not have fully d...
-
MP-RAGE stands for Magnetisation Prepared RApid Gradient Echo. MP-RAGE is a 3DFT contrast prepared gradient echo sequence. The T1 weig...
1 comment:
Nice post
MRI Scan Cost in Delhi may vary from Rs. 3000/- to Rs.8000/- in 1.5 Tesla to 3 Tesla according to for one part of the body. Now book your scan through easybookmylab
Post a Comment