The peak blood concentration of injected gadopentetate dimeglumine depends on the bolus injection rate (12–14). The signal intensity obtained with the spoiled GRE sequences (3D fast field echo and 3D turbo field echo) increases according to the gadopentetate dimeglumine concentration . Therefore, with a spoiled GRE sequence, a fast injection rate (2–5 mL/sec) is used. However, a nonspoiled GRE sequence does not show high signal intensity when the maximum gadopentetate dimeglumine concentration reaches more than 2 mmol/L. Therefore, with a nonspoiled GRE sequence, slow injection of nondiluted gadopentetate dimeglumine or rapid injection of diluted gadopentetate dimeglumine would be recommended.
Injection Rate of Dynamic MR angiogram
The peak blood concentration of injected gadopentetate dimeglumine depends on the bolus injection rate (12–14). The signal intensity obtained with the spoiled GRE sequences (3D fast field echo and 3D turbo field echo) increases according to the gadopentetate dimeglumine concentration . Therefore, with a spoiled GRE sequence, a fast injection rate (2–5 mL/sec) is used. However, a nonspoiled GRE sequence does not show high signal intensity when the maximum gadopentetate dimeglumine concentration reaches more than 2 mmol/L. Therefore, with a nonspoiled GRE sequence, slow injection of nondiluted gadopentetate dimeglumine or rapid injection of diluted gadopentetate dimeglumine would be recommended.
Subscribe to:
Post Comments (Atom)
Popular Posts
-
Regional Saturation Bands Regional saturation employs a 90° RF pulse which, when combined with a gradient orthogonal to the imaging p...
-
Normal MRI Anatomy The pectoralis tendon is best seen on axial T1 and T2-weighted images as a curvilinear low-signal band inserting o...
-
Axial Plane: Prescribe plane perpendicular to midshaft of the proximal phalanx of the thumb. Scan from 1st carp-metacarpal joint th...
-
MR Arthrogram Protocol Axial T1 SE Axial T1 SE (fat sat) Sagittal Obl T1 SE (fat sat) Coronal Obl T1 SE (fat sat) Coronal Obl T2 TSE ...
-
The T1-shortening effects of gadolinium within circulating blood results in a transient increased signal intensity in vascular structure...
-
MRI of the Right Lower Leg Clinical details: Technique: Multiplanar multisequence study including T1,T2, STIR and GRE weigh...
-
--> Routine shoulder protocols are the most variable, but most include SHOULDER MRI SEQUENCES ...
-
Contrast for arthrogram: 10 cc omnipaque 300 10 cc normal saline 0.1 cc omnihance For knee, double the quantities. Joints...
-
IN THIS ARTICLE: MRI Brain Axial Planning/Reference Lines MRI Brain Coronal Planning/Reference Lines MRI Brain Sagital Planning/Re...
No comments:
Post a Comment